CPT code 93306

CPT 93306 is the code for a complete transthoracic echocardiogram (TTE) that includes spectral Doppler and color flow Doppler. It is the most common adult echocardiogram code, which makes it a frequent target for coding errors and audits. This guide explains what it includes and how to bill it.

What CPT 93306 describes

93306 reports a transthoracic echocardiogram performed with real-time two-dimensional imaging, with image documentation, and including M-mode recording when performed, plus complete spectral Doppler and color flow Doppler.

Because Doppler and color flow are already part of 93306, they are not reported separately. Reporting Doppler or color flow add-on codes (such as 93320 or 93325) on top of 93306 is a common unbundling error.

CodeDescription
93306Complete TTE with spectral and color flow Doppler
93307Complete TTE with 2D imaging, without Doppler
93308Follow-up or limited TTE, 2D only
93303, 93304Transthoracic echocardiography for congenital cardiac anomalies

Choose the code that matches what was actually performed and documented. A limited study cannot be billed as a complete study.

Documentation requirements

  • The reason for the study and the clinical indication

  • A complete study: all required views and the structures evaluated

  • Doppler and color flow recorded, with images stored

  • A signed interpretation with findings, measurements and conclusions

  • The ordering provider's information

If a study is incomplete because of poor image quality or patient condition, the record should say why, and the code may need to change.

Modifiers

  • 26 (professional component): when the provider only interprets the study

  • TC (technical component): when the facility bills the equipment and technologist

  • 76 or 77: repeat procedure on the same day, by the same or a different provider

  • 59: only when a distinct, separately documented service applies

When one entity bills both parts, the claim is global and has no 26 or TC.

Medical necessity

Payers want a diagnosis that supports the test, such as heart murmur, shortness of breath, chest pain, heart failure, valve disease or monitoring after a cardiac event. A repeat echocardiogram with no change in condition is a common denial reason.

Common billing errors

  • Billing 93306 when Doppler was not performed or documented

  • Reporting Doppler or color flow add-ons separately

  • Using a complete code for a limited study

  • Missing 26 or TC when only one part is provided

  • A diagnosis that does not support medical necessity or frequency

Quick reference

ItemDetail
CPT code93306
StudyComplete TTE with spectral and color flow Doppler
Do not addSeparate Doppler or color flow codes
Common modifiers26, TC, 76, 77

Step by step: billing 93306

  1. Confirm the study was complete. The report should show the required views and the structures evaluated.

  2. Confirm Doppler and color flow were performed and recorded.

  3. Select the code. Report 93306 for a complete study with spectral and color flow Doppler. If Doppler was not performed, the code changes.

  4. Do not add Doppler codes. Doppler and color flow are already part of 93306.

  5. Add 26 or TC only when the interpretation and the technical component are billed by different entities.

  6. Link a diagnosis that supports medical necessity.

Example scenarios

These examples are illustrations, not patient records.

  • Complete study. A cardiologist orders an echocardiogram for shortness of breath. The study includes full imaging with spectral and color flow Doppler. Report 93306.

  • Limited study. A follow-up study checks one question only, such as a pericardial effusion. It is limited, so a limited code applies and not 93306.

  • Study without Doppler. A complete two-dimensional study is performed without Doppler. 93307 describes this study, not 93306.

  • Split billing. A hospital owns the equipment and an independent cardiologist reads the images. The hospital bills TC and the cardiologist bills 26.

Frequently asked questions

Can I bill Doppler separately with 93306? No. It is included in the code.

What if the study is incomplete? The record should explain why, such as poor image quality, and the code may need to reflect a limited study.

How often can an echocardiogram be repeated? Payers set limits. A repeat with no change in the patient's condition is a common denial. Document the clinical reason for any repeat.

What diagnoses support an echocardiogram? Commonly a heart murmur, shortness of breath, chest pain, heart failure or valve disease. The payer's policy lists accepted indications.

Fewer denials on cardiology claims

Cardiology imaging claims depend on exact code selection and documentation. MedBiller Texas reviews your claims and denials and shows where the pattern is costing you revenue. Request a free audit.

MedBiller Texas

Published by MedBiller Texas

Medical billing and revenue cycle management for healthcare practices, from our office in Grapevine, Texas.

About us

Want us to check how your practice bills this?

Request a free audit. We review your claims and denials and show you where revenue is slipping.

What happens after you ask

  1. 1We reply within 24 hours
  2. 2A short call about your claims and goals
  3. 3You receive a written audit report
Or email info@medbillertexas.com

Where is your revenue leaking?

Cookie preferences

Choose what we may use. You can change this any time from “Cookie settings” at the bottom of every page.