CPT 77067: Screening Mammogram Billing
How to bill CPT 77067 for a bilateral screening mammogram: the 77063 tomosynthesis add-on, modifiers, Z12.31 diagnosis coding and common mistakes.
- Published by
- MedBiller Texas
- Published
- Updated
- Reading time
- 4 min

Screening mammography is one of the most common preventive imaging services, and a small coding mistake can turn a covered preventive exam into a denied claim. CPT 77067 is the code for a bilateral screening mammogram. This guide explains what it covers, when to use it, how tomosynthesis changes the claim, and the errors that cause the most denials.
What CPT 77067 describes
CPT 77067 reports a screening mammography, bilateral, with a two-view study of each breast, including computer-aided detection (CAD) when it is performed. Because CAD is part of the code, it is not reported separately.
77067 took effect in 2017. It replaced the older screening codes 77057 and G0202, so claims still using those codes will be rejected.
When to use 77067
Use 77067 when a patient with no breast symptoms has a routine screening exam of both breasts. If a patient has a lump, pain, nipple discharge or any other sign or symptom, or is being called back after an abnormal screen, the exam is diagnostic and a diagnostic mammography code applies instead:
77065: diagnostic mammography, unilateral, including CAD
77066: diagnostic mammography, bilateral, including CAD
Medicare covers one screening mammogram a year for women age 40 and older, and most commercial plans cover screening as a preventive service with no patient cost sharing. Always confirm frequency limits and age rules with the payer.
Documentation checklist
The record should show:
The reason for the exam is screening, with no breast symptoms reported
Both breasts were imaged, with two views of each
Whether CAD was used in the interpretation
The radiologist's findings and any follow-up recommendation
The screening diagnosis code, Z12.31 (encounter for screening mammogram for malignant neoplasm of breast)
Adding tomosynthesis: CPT 77063
Digital breast tomosynthesis (3D mammography) is reported with 77063, an add-on code for bilateral screening tomosynthesis. Two rules matter:
77063 can never be billed alone. It is reported in addition to 77067.
For diagnostic exams, tomosynthesis uses different codes (77061 and 77062), reported with 77065 or 77066.
Medicare and some payers use their own HCPCS codes for tomosynthesis, so check each payer's policy before submitting.
Modifiers that may apply
| Modifier | Use |
|---|---|
| 26 | Professional component only (the radiologist's interpretation) |
| TC | Technical component only (equipment, technologist and facility) |
| GG | Medicare: a screening mammogram and a diagnostic mammogram on the same patient on the same day |
When one entity bills both parts, the claim is global and needs no 26 or TC. Modifier 59 is not normally needed for 77067.
Common mistakes to avoid
Using 77067 for a patient with symptoms or a callback exam (use 77065 or 77066)
Billing 77063 without 77067
Forgetting modifier GG when a Medicare screening becomes diagnostic the same day
Submitting the retired codes 77057 or G0202
Leaving off the Z12.31 diagnosis, or using a diagnosis code that does not support screening
Exceeding the payer's frequency limit without documented high-risk status
Quick reference
| Item | Detail |
|---|---|
| CPT code | 77067 |
| Service | Bilateral screening mammogram, 2 views per breast, with CAD when performed |
| Tomosynthesis add-on | 77063 (screening, bilateral) |
| Diagnostic equivalents | 77065 (unilateral), 77066 (bilateral) |
| Screening diagnosis | Z12.31 |
| Usual frequency | Once a year, subject to payer rules |
Step by step: billing a screening mammogram
Confirm it is a screening. The patient has no symptoms and is not being called back for an abnormal result.
Check coverage and frequency with the payer before the exam, including age rules and the last screening date.
Choose the code. Report 77067 for the bilateral screening exam. Add 77063 only if screening tomosynthesis was also performed.
Attach the diagnosis. Z12.31 describes the encounter for a screening mammogram.
Decide the claim type. One entity billing both the interpretation and the equipment submits a global claim. If the radiologist and the facility bill separately, use 26 and TC.
Confirm the documentation shows two views of each breast, CAD use when performed and the radiologist's report.
Example scenarios
These examples are illustrations, not patient records.
Routine annual screening. A patient with no symptoms has a bilateral screening exam with CAD. Report 77067 with Z12.31.
Screening with 3D imaging. The same patient also has screening tomosynthesis. Report 77067 and add 77063.
A lump reported at check-in. The exam is no longer a screening. A diagnostic code applies, 77066 for both breasts, and the diagnosis reflects the symptom.
Medicare screening that becomes diagnostic. A radiologist adds diagnostic views the same day. Medicare's modifier GG is used for this situation.
Frequently asked questions
Does 77067 include CAD? Yes. Computer-aided detection is part of the code when it is performed, so it is not billed separately.
Can 77063 be billed by itself? No. It is an add-on code reported with 77067.
Why do screening mammogram claims get denied? The most common reasons are exceeding the payer's frequency limit, a symptomatic patient billed as a screening, a missing or wrong diagnosis code and use of the retired codes 77057 or G0202.
Is a screening mammogram free to the patient? Many plans cover it as a preventive service with no cost sharing, but a diagnostic exam can carry patient cost sharing. Confirm benefits before the visit.
Get mammography claims paid the first time
Imaging claims are denied for small, preventable reasons: the wrong code family, a missing diagnosis, a frequency limit nobody checked. MedBiller Texas reviews claims, denials and receivables for imaging and other specialty practices, and a free audit shows where revenue is slipping. Request a free audit.
Topics
Published by MedBiller Texas
Medical billing and revenue cycle management for healthcare practices, from our office in Grapevine, Texas.